BrandName: EPI KRAL GREYLINE EMCO KEM PROCES-DATA A/S Aliamag Electromagnetic Flowmeter
   
Flowmeter Series > KEM > C-FLOW > KCM TRANSDUCER
 
Introduction   KCM Transducer   KCE 4000 Transmitter
 
P.1 P.2 P.3
 
KCM Transducer 
 
Type Dia Meas. range, kg/h kg/min
KCM 0030 4 mm 4.5 up to 30 0.075 up to 5
KCM 0060 4 mm 9.0 up to 60 0.05 up to 10
KCM 1500 8 mm 25 up to 1,500 0.40 up to 25
KCM 3000 8 mm 50 up to 3,000 0.90 up to 50
KCM 6000 12 mm 60 up to 6,000 1 up to 100
KCM 20K 18 mm 200 up to 20,000 3.3 up to 334
KCM 40K 28 mm 400 up to 40,000 11 up to 667
KCM 60K 34 mm 600 up to 60,000 16.6 up to 1,000
 
Technical Data - KCM 0300 to KCM 3000
 
medium temperature: up to +125¢XC
connections:
  • female threads G1/2"
  • adapters for flanges, diary or tri-clamp connectors
operating pressure: max. 350 bar
material: stainless steel as per DIN 1.4571 (AISI 316 Ti)
ingress protection : IP 67
electrical connection:
  • 9-pin flange plug
  • compact version with integral transmitter
max cable length: 30 metres between tranducer and transmitter
Ex-protection: EX II 2G EEx ib IIC T2¡VT4
weight: KCM 300 and 600: 4.1 kg
KCM 1500 and 3000: 8.8 kg
 
Technical Data - KCM 6000 to KCM 60K
 
End connections: flanges acc. EN 1092, ANSI B16.5, DIN2512
Nominal pressure:

PN 40, ANSI 150 / 300 lbs

Process temperature: -40¢XC to +180¢XC (-40¢XF to +356¢XF)
Ambient temperature: -40¢XC to +60¢XC (-40¢XF to +140¢XF)
Ingress protection: : IP 65 (EN60529) (NEMA 4X)
Materials Flow tubes, splitter flanges: 1.4404 (316 L)/1.4571 (316 Ti)
Housing: cast iron
 
Accuracy
 
Type KCM 300 KCM 600 KCM 1500 KCM 3000 KCM 6000 KCM 20K KCM 40K KCM 60K
No. of measuring tubes
(arrangement)
2 (serial) 2 (parallel) 2 (serial) 2 (parallel) 2 (parallel) 2 (parallel) 2 (parallel) 2 (parallel)
Basic error
(referring to instant. flow)
¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5%
Zero stability
0.05 kg/h 0.12 kg/h 0.3 kg/h 0.5 kg/h 0.6 kg/h 2.0 kg/h 4 kg/h 6 kg/h